| Model |
General Description |
Replacement |
| Series 42 Level-Log |
Circular chart recorder with an internal 10 pf to 500 pf analog capacitance transmitter. |
None |
| 951-B Proximity Meter |
Test equipment. |
None |
| Level -Tek 101 - B |
Remote (5 ft.) with lights, LLFS with no differential. Explosion-proof enclosure, Class II, Groups E, F & G. |
304B, 310 or 5100 |
| Level -Tek 101 - W |
Same as 101-B, except weather-tight. |
304B, 310 or 5100 |
| Level -Tek 102 - B |
Same as 101-B, except HLFS. |
304B, 310 or 5100 |
| Level -Tek 102- W |
Same as 101-W, except HLFS. |
304B, 310 or 5100 |
| Level -Tek 1010 - E |
Remote (5 ft.), with or without lights, no differential. Explosion-proof enclosure, Class I. Groups C & D, LLFS. |
304B, 310 or 5100 |
| Level -Tek 1020 - E |
Same as 1010-E except HLFS. |
304B, 310 or 5100 |
| Any Level-Tek above with 'F' on end of number |
Same as basic above, but with differential. |
304B, 310 or 5100 |
| Any Level-Tek above with 'T' on end of number |
Same as basic above, but with time delay. |
304B, 310 or 5100 |
| Level -Tek 107 - W |
Remote (5 ft.), hi-Sensitivity, LLFS with lights. Has some electronics on probe. Uses standard 3 wire cable. Weather-tight. |
310 or 5100 |
| Level -Tek 107 - E |
Same as 107-W, except in explosion-proof enclosure, Class I, Groups C & D. |
310 or 5100 |
| Level -Tek 107 - B |
Same as 107-E, except in explosion-proof enclosure, Class II, Groups E, F & G. |
310 or 5100 |
| Level -Tek 108 - W |
Same as 107-W, except HLFS. |
310 or 5100 |
| Level -Tek 108 - E |
Same as 107-E, except HLFS. |
310 or 5100 |
| Level -Tek 108 - B |
Same as 107-B, except HLFS. |
310 or 5100 |
| Level -Set 111 - W |
Capacitance transmitter with pneumatic 3 to 15 psi output. 6 pf span. Direct-acting. Weather-tight housing. LLFS. |
167-A and 443A or 445A |
| Level -Set 111 - E |
Same as 111-W, except in explosion-proof housing. Has adjustments through case. |
167-A and 443A or 445A |
| Level -Set 111 - YE |
Same as 111-W, except adjustments are internal. |
167-A and 443A or 445A |
| Level -Set 112 - W |
Same as 111-E, except HLFS. |
167-A and 443A or 445A |
| Level -Set 112 - E |
Same as 111-E, except HLFS. |
167-A and 443A or 445A |
| Level -Set 112 - YE |
Same as 111-YE, except HLFS. |
167-A and 443A or 445A |
| Level -Tek 303A |
Direct mounted, explosion-proof enclosure. 15 to 75 pf control range SPDT relay output. |
304B and 318A |
| Level -Tek 304 |
Direct conversion to 304B. |
304B |
| Level -Tek 304A |
Direct conversion to 304B |
304B |
| Level -Tek 305 |
Two-piece unit with detector mounted on probe and indicator remotely mounted. Adjustment range 10 to 100 pf. |
304B, 310 or 5100 |
| 305 - A |
Fixed, minimum differential. |
304B, 310 or 5100 |
| 305 - F |
Adjustable differential. |
304B, 310 or 5100 |
| 305 - ( ) ( ) - W ( ) |
Weather-tight enclosure with red/#cccc99 lights. |
310 or 5100 |
| 305 - ( ) ( )- N ( ) |
Explosion-proof enclosure with lights. |
310 or 5100 |
| 305 - ( ) ( ) - M ( ) |
3x6 panel mount with single light. |
310 or 5100 |
| 305 - ( ) ( ) - P ( ) |
3x6 panel mount with duplex lights. |
310 or 5100 |
| 306 - A3 - W1 |
BS & W, on/off monitor with direct mounted explosion-proof detector and weather-tight display (305 tight style with red/#cccc99 lights). |
None |
| 306 - A3 - W1 - T |
Same as 306-A3-W1, except has a three (3) second time delay. |
None |
| 306 - A3 - N1 |
Same as 306-A3-W1, except explosion-proof display enclosure (305 style). |
None |
| 306 - A3 - N1 -T |
Same as 306-A3-N1, except has a three (3) second time delay. |
None |
| 307 - W1 |
BS & W, on/off monitor with direct mounted explosion-proof detector and weather-tight display. Has SPDT relay output. 0% to 2% BS & W detection. |
None |
| 307 - N1 |
Same as 307-W1, except display enclosure is explosion-proof. |
None |
| 308 - |
BS & W measurement, continuous output monitor. |
None |
| 308 - A ( ) - ( ) ( ) |
1 to 5 mADC output. |
None |
| 308 - B ( ) - ( ) ( ) |
4 to 20 mADC output. |
None |
| 308 - C ( ) - ( ) ( ) |
10 to 50 mADC output. |
None |
| 308 - ( ) 1 - ( ) ( ) |
Weather-tight display (158A WT style). |
None |
| 308 - ( ) 2 - ( ) ( ) |
Explosion-proof display. |
None |
| 308 - ( ) 3 - ( ) ( ) |
Weather-tight display with time delay. |
None |
| 308 - ( ) ( ) - A ( ) |
0% to 5% span |
None |
| 308 - ( ) ( ) - B ( ) |
0% to 10% span |
None |
| 308 - ( ) ( ) - ( ) 1 |
2 in. pipe size. |
None |
| 308 - ( ) ( ) - ( ) 2 |
3 in. pipe size. |
None |
| 351A |
Conductivity switch with 12 in. bare probe. |
352 with 740-A1-A12 |
| Level -Tel 154 |
Remote unit up to 200 ft. from probe using 50 ohm coaxial. Has some electronics in probe condulet. -W unit is weather-tight, -E unit is explosion-proof. Optional meters available, some with internal relays. |
5000A, 7000 or 158A |
| Level -Tel 155 |
Two-piece, analog transmitter with explosion-proof probe mounted detector and remote mounted display. Span 10 pf to 3200 pf. |
167, 210KB102, 5000A or 7000 |
| Level -Tel 155 - B |
3x6 display with one high alarm relay. |
5000A or 7000 |
| Level -Tel 155 - C |
3x6 display with one low alarm relay. |
5000A or 7000 |
| Level -Tel 155 - D |
3x6 display with two alarm relays. |
5000A or 7000 |
| Level -Tel 155 - E |
Explosion-proof display, Class I Division 1, Groups C & D. |
167 - X - 2 |
| Level -Tel 155 - F |
Weather-tight display (158A style). |
167 - X - 2 |
| Level -Tel 155 - G |
3x6 display with no alarm. |
167 - X - 2 |
| Level -Tel 156 |
Two-piece, analog transmitter with explosion-proof probe mounted detector and remote mounted display. Span 10 pf to 2000 pf. |
167, 210KB102, 5000A or 7000 |
| 156 - A ( ) |
1 to 5 mADC output. |
None |
| 156 - B ( ) |
4 to 20 mADC output. |
167, 5000A or 7000 |
| 156 - C ( ) |
10 to 50 mADC output. |
167or 5000A |
| 156 - D ( ) |
0 to 4 mADC output. |
None |
| 156 - F ( ) |
Special. |
Consult factory |
| 156 - ( )1 |
Self-contained, probe mounted transmitter, blind, 120 VAC. |
167 - B |
| 156 - ( )2 |
Same as 156 -( )1 except 26.5 VDC transmitter. |
167 - A |
| 156 - ( )3 |
26.5 VDC transmitter with weather-tight display (158A style). |
167 - A - 2 |
| 156 - ( )4 |
26.5 VDC transmitter with explosion-proof display. |
167 - A - 2 |
| 156 - ( )5 |
26.5 VDC transmitter with 3x6 display. |
167 - A - 2 |
| 156 - ( )6 |
26.5 VDC transmitter, 3x6 display with one alarm relay. |
5000A |
| 156 - ( )7 |
26.5 VDC transmitter, 3x6 display with two alarm relays. |
5000A |
| 157A |
4-wire direct mounted analog transmitter. |
167-B or C, 5000A or 7000 |
| 159 |
Anti-coat 4-wire remote transmitter. |
158A, 5000A or 7000 |
| 160 |
Anti-coat 2-wire remote transmitter. |
167-A |
| 161 |
Remote Mounted transmitter with indicator. Has Anti-Coating circuitry |
158A or 7000 |
| 162 |
4-wire dielectric compensation transmitter. |
None |
| 164 |
4-wire low-cost analog direct mounted transmitter. |
167-B, C, or 5000A |
| 165 |
Ultrasonic transmitter. |
None |
| 166 |
Submerence flow transmitter. |
None |
| 168 |
4-wire low-cost analog remote transmitter. |
158A, 5000A or 7000 |
| 515 |
Controller for tilt probe |
310, 5100 & 728B |
| 900-600-304 |
Duplex detector for Model 162. |
None |
| 5001 |
Microprocessor-based on/off level detector with one DPDT relay. |
5100 |
| 5002 |
Microprocessor-based on/off level detector with two DPDT relays. |
5400A |
| 5003 |
Microprocessor-based on/off level detector with three DPDT relays. |
5400A |
| M5008 |
Multipoint Controller |
None |